Study of Gaseous Ammonia Supply Rate Calculation Method for Urea-SCR Catalytic Reactors
DOI:
Key Words:IC engine  SCR catalyst  dynamic conversion efficiency  temperature window
Author NameAffiliation
LI Jun,SHEN Boxi,LI Zhijun,TAO Hanguo,LIU Yue 1.State Key Laboratory of Engine Combustion, Tianjin University, Tianjin 300072, China 2.China Automotive Technology & Research Center, Tianjin 300300, China 
Hits: 3238
Download times: 1940
Abstract:Based on the research of the gaseous ammonia equilibrium equation in SCR reaction as well as the functional relationship between SCR dynamic conversion rate and ammonia storage amount, a quantitative calculation method for gaseous ammonia supply rate and urea deposit rate is proposed by comparing the catalyst bench evaluation and performance simulation calculation. Using this method, the calculation of specific bench test data shows that there is a certain degree of delay in the decomposition of urea solution at a catalytic converter inlet temperature of 300℃ and space velocity of 40000h-1, but the final decomposition is quite complete. This study provides an effective tool for analyzing the decomposition conditions of urea solution and its effect on engine bench evaluations.
View Full Text  View/Add Comment  Download reader