Optimization and Application of Thermal Management System in Engine Bench Test |
DOI: |
Key Words:IC engine engine bench test eddy current dynamometer thermal management system Flowmaster simulation |
|
Hits: 3355 |
Download times: 2212 |
Abstract:To prevent engine coolant temperature fluctuation and insufficient water supply in an eddy current dynamometer during engine bench tests, a second stage cooling system was added to engine pilot as a solution. First, a simulation of the system was performed with the Flowmaster based on relevant parameters to optimize the system, and then a comparison experiment was conducted to verify the simulation. The results show that the temperature of the engine coolant can be stable within±3 ℃, water flow rate in the dynamometer is 4 m3/h more than before. |